Shenzhen Olen Electric Co., Ltd.
Address: 201, Building 3, Xinzhongtai Cultural Pioneer Park, Caiyun Road, Longcheng Street, Longgang District, Shenzhen
Phone:+86-400-7887-897 +86-18938020950 Manager Sun
FAX:+86-0755-27495336
product description
OD6L series inverter is a general-purpose high-performance vector inverter, mainly used to control and adjust the speed and torque of three-phase AC asynchronous motor, using high-performance vector control technology, low speed and high torque output, with good dynamic characteristics , Super overload capacity, rich and powerful functions, stable and reliable performance.
Input voltage: three-phase AC380V; three-phase AC220V;
Power range: 0.75~560KW.
Overload capacity: 150% rated load 60S, 180% rated load 3S.
Control mode: VF, vector without PG, vector with PG.
Drive motor: ordinary asynchronous motor, frequency conversion asynchronous motor.
GP model: Support GP unity.
High speed stability accuracy and wide speed range
Speed stability accuracy: ±0.5% (SVC), ±0.02% (FVC)
Speed range: 1:100 (SVC), 1:1000 (FVC)
Torque response: <20MS (SVC), <5MS (FVC)
Large torque at low speed, small torque ripple
Independent air duct design
Features
① High response of torque and speed control
1.1 Under PG open loop vector control, the torque response is less than 20ms. With PG closed-loop vector control, the torque response is <5ms.
1.2 Applicable to the occasions of quick start and quick stop, and sudden load and unload.
1.3 Sudden increase in load, rapid response of torque, and high speed stability.
②Internationally advanced speed sensorless magnetic flux vector algorithm
2.1 Speed sensorless vector control, can block the rotor, the output torque of the motor is 150% of the rated torque of the motor.
2.2 High starting torque characteristics.
③Reliable torque limit
3.1 When it is necessary to protect the machinery, the output torque is limited by the high-precision torque limiting function under vector control.
3.2 When there is a sudden load change, the machinery is protected by the torque limiting function.
④ Wave-by-wave current limiting function
4.1 Overcurrent alarm caused by sudden load or interference can be effectively avoided to protect the safety of the equipment.
⑤ Speed tracking function
Speed tracking smooth start
⑥Instant stop function
6.1 This function only reduces the output frequency of the inverter at the moment of power failure, but reduces the output frequency, feeds back energy through the load, and supplements the voltage reduction to maintain the inverter to continue to work in a short time.
6.2 Applicable to chemical fiber, textile and other industries.
⑦Customized parameters
7.1 Users can define commonly used function code parameters into the inverter to automatically form a set of commonly used parameters, which is convenient for debugging.
⑧ Configure rich motor self-learning function
Dynamic self-learning
Stop self-learning, suitable for the state where the connection between the motor and the device is not good
product information
Product installation inch
变频器型号 | 外形及安装尺寸(mm) | 重量 (kg) | ||||||
A | B | H | H1 | W | D | Φd | ||
| 三相380V | |||||||
OD6L-R75G/1R5PT4 |
113 |
172 |
186 |
/ |
125 |
164 |
ø5.0 |
1.1 |
OD6L-1R5G/2R2PT4 | ||||||||
OD6L-2R2G/3R7PT4 | ||||||||
OD6L-3R7G/5R5PT4 |
148 |
236 |
248 |
/ |
160 |
183 |
ø5.0 |
2.5 |
OD6L-5R5G/7R5PT4 | ||||||||
OD6L-7R5G/011PT4 | ||||||||
OD6L-011G/015PT4 |
190 |
305 |
322 |
/ |
208 |
192 |
ø6 |
6.5 |
OD6L-015G/018PT4 | ||||||||
OD6L-018G/022PT4 |
230 |
440 |
|
455 |
290 |
218 |
Ø7 |
|
OD6L-022G/030PT4 | ||||||||
OD6L-030G/037PT4 | ||||||||
OD6L-037G/045PT4 |
230 |
540 |
|
555 | 320 |
240 |
Ø10 |
|
OD6L-045G/055PT4 | ||||||||
OD6L-055G/075PT4 |
320 |
610 |
|
635 | 410 |
239 |
Ø12 |
|
OD6L-075G/090PT4 | ||||||||
OD6L-090G/110PT4 |
320 |
630 |
|
654 | 460 |
340 |
Ø12 |
|
OD6L-110G/132PT4 | ||||||||
OD6L-132G/160PT4 |
320 |
856 |
|
886 |
520 |
385 |
Ø13 |
|
OD6L-160G/200PT4 | ||||||||
OD6L-200G/220PT4 | ||||||||
OD6L-220G/250PT4 |
500 |
1313 |
|
1350 |
750 |
432 |
Ø13 |
|
OD6L-250G/280PT4 | ||||||||
OD6L-280G/315PT4 | ||||||||
OD6L-315G/355PT4 |
500 |
1410 |
|
1450 |
850 |
432 |
Ø13 |
|
OD6L-355G/400PT4 | ||||||||
OD6L-400G/450PT4 |
OD6L frequency converter technical specification
项 目 | 规 格 | ||
基本功能 | 最高频率 | 0.00Hz~3200.00Hz | |
载波频率 | 0.5kHz~16kHz | ||
输入频率分辨率 | 数字设定:0.01Hz | ||
控制方式 | 开环矢量控制(SVC)、闭环矢量控制(FVC)、V/F控制 | ||
启动转矩 | G 型机:0.3Hz/150%(SVC);0Hz/180%(FVC) | ||
调速范围 | 1:200(SVC) 1:1000(FVC) | ||
稳速精度 | ±0.5%(SVC) ±0.02%(FVC) | ||
转矩控制精度 | ±5%(FVC) | ||
过载能力 | G 型机:150% 额定电流 60s;180% 额定电流 3s | ||
转矩提升 | 自动转矩提升;手动转矩提升:0.1%~30.0% | ||
V/F 曲线 | 三种方式:直线型;多点型;N 次方型 V/F 曲线 | ||
V/F 分离 | 2种方式:全分离、半分离 | ||
加减速曲线 | 直线或 S 曲线加减速方式。四种加减速时间,加减速时间范围 0.00s~65000s | ||
直流制动 | 直流制动频率:0.00Hz~最大频率 | ||
点动控制 | 点动频率范围:0.00Hz~50.00Hz。点动加减速时间 0.00s~65000s | ||
简易 PLC、多段速运行 | 通过内置 PLC 或控制端子实现最多16段速运行 | ||
内置 PID | 可方便实现过程控制闭环控制系统 | ||
自动电压调整(AVR) | 当电网电压变化时,能自动保持输出电压恒定 | ||
过压过流失速控制 | 对运行期间电流电压自动限制,防止频繁过流过压跳闸 | ||
快速限流功能 | 最大限度减小过流故障,保护变频器正常运行 | ||
转矩限定与控制 | “挖土机”特性,对运行期间转矩自动限制,防止频繁过流跳闸;矢量模式可实现转矩控制 | ||
个性化功能 | 出色的性能 | 以高性能的电流矢量控制技术实现异步电机控制 | |
瞬停不停 | 瞬时停电时通过负载回馈能量补偿电压的降低,维持变频器短时间内继续运行 | ||
快速限流 | 避免变频器频繁的出现过流故障 | ||
定时控制 | 定时控制功能:设定时间范围 0.0Min~6500.0Min | ||
多线程总线支持 | 目前支持:RS-485总线,后续将支持profibus-dp、canOpen等总线 | ||
电机过热保护 | AI3可以接PT100或PT1000输入电机温度模拟量,实现电机过热保护 | ||
多编码器支持 | 支持增量式编码器和旋转变压器。 | ||
强大的后台软件 | 支持变频器参数操作及虚拟示波器功能。通过虚拟示波器可实现对变频器内部状态的图形监视 | ||
运行 | 命令源 | 操作面板给定、控制端子给定、串行通讯口给定,可通过多种方式切换 | |
频率源 | 10 种频率源:数字给定、模拟电压给定、模拟电流给定、脉冲给定、串行口给定、面板电位器给定等,可通过多种方式切换 | ||
辅助频率源 | 10 种辅助频率源,可灵活实现辅助频率微调、频率合成 | ||
输入端子 | 标准: | ||
输出端子 | 标准: | ||
显示与键盘操作 | LED 显示 | 显示参数 | |
参数拷贝 | 可通过上位机软件实现参数拷贝功能 | ||
按键锁定和功能选择 | 实现按键的部分或全部锁定,定义部分按键的作用范围,以防止误操作 | ||
保护功能 | 上电电机短路检测、输入输出缺相保护、过流保护、过压保护、欠压保护、过热保护、过载保护等 | ||
环境 | 使用场所 | 室内,不受阳光直晒,无尘埃、腐蚀性气体、可燃性气体、油雾、水蒸汽、滴水或盐份等 | |
海拔高度 | 低于 1000m | ||
环境温度 | -10℃~+40℃(环境温度在 40℃~50℃,请降额使用) | ||
湿度 | 小于 95%RH,无水珠凝结 | ||
振动 | 小于 5.9m/s2(0.6g) | ||
存储温度 | -20℃~+60℃ |
Previous:NO